Authors
Pauline Delsol, Michel Le Gall, Stéphane Barthélemi
Published in
L' Orthodontie francaise. Volume 97. Issue 2. Pages 241-253. Jul 21, 2026.
Abstract
Eruption anomalies of permanent molars, particularly mesial inclinations that cause mechanical impaction, represent a common clinical challenge in orthodontics. Traditionally, the lack of coronal access and the difficulties associated with traction have led to routine extractions, compromising tooth preservation and the possibility of achieving a functional occlusion comprising at least 28 teeth. The molar uprighting device offers a conservative alternative based on the use of a heat-activated 0.014-inch nickel-titanium wire (shape memory effect heat-activated NiTi), inserted into the interproximal space and then bonded to the adjacent tooth, which serves as anchorage. Thanks to its superelasticity, the wire delivers gentle, continuous force, generating distal tipping movement that enables gradual uprighting of the mesially tipped molar without direct access to its crown.
Ten patients presenting with a mesially tipped molar impacted against the adjacent tooth, with no communication with the oral cavity, were included in this study. A 0.014-inch-diameter heat-activated shape-memory nickel-titanium (NiTi) wire was inserted vertically into the interproximal space between the two teeth, then bent over and bonded to the occlusal surface of the anterior tooth already in occlusion.
The clinical results presented demonstrate reproducible uprighting, predictable vertical positioning, and functional eruption, with no iatrogenic complications or periodontal or root damage. Indications for the molar uprighting device include mesially tipped third molars, impacted second molars without coronal access, maxillary first molars impacted beneath deciduous teeth, as well as treatment plans involving extraction where preservation of the third molars is desired.
The molar uprighting device therefore forms part of a treatment approach that prioritizes the preservation of the dentition, reduces indications for tooth extraction, and optimizes occlusion. Owing to its simplicity, reliability, and non-invasive nature, it represents a significant contribution to the orthodontic management of molar eruption disorders.
PMID:
43036987
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 4
- Comments 0