Abstract
A major limiting factor in functional enzyme engineering is the rate of variant evaluation, typically reaching 104-105 assays daily through traditional microplate and colony screening. Droplet microfluidics encapsulates cells or library members in millions of picoliter water-in-oil droplets. These droplets serve as isolated bioreactors, linking a variant's genotype to phenotype and enabling the screening of millions of reactions daily. This chapter details a reproducible ultra-high-throughput screening workflow based on three key requirements: in-droplet fluorescent readout of target activity, oxygenated incubation for cell growth and product formation, and sensitive optical-fiber detection for fluorescence-activated droplet-sorting. We provide a case study of a nonribosomal peptide synthetase producing the membrane-active peptide gramicidin S, whose activity is reported by calcein-filled sensor liposomes upon permeabilization. The protocol includes device fabrication, single-cell encapsulation, incubation, detection, sorting, and hit recovery. The screening workflow can be adapted to other enzymatic assays, provided they meet the three screening requirements.
PMID:
43039622
Bibliographic data and abstract were imported from PubMed on 17 Nov 2026.