Air embolism in CT-guided transthoracic needle biopsy: emphasis on pulmonary vein injury.

Created on 18 Nov 2026

Authors

Yura Ahn, Sang Min Lee, Hwa Jung Kim, Jooae Choe, Sang Young Oh, Kyung-Hyun Do, Joon Beom Seo

Published in

European radiology. Volume 32. Issue 10. Pages 6800-6811. Epub Aug 25, 2022.

Abstract

To assess whether pulmonary vein injury is detectable on CT and associated with air embolism after percutaneous transthoracic needle biopsy (PTNB) in a tertiary referral hospital.
Between January 2012 and November 2021, 11,691 consecutive CT-guided PTNBs in 10,685 patients were retrospectively evaluated. Air embolism was identified by reviewing radiologic reports. Pulmonary vein injury was defined as the presence of the pulmonary vein in the needle pathway or shooting range of the cutting needle with the presence of parenchymal hemorrhage. The association between pulmonary vein injury and air embolism was assessed using logistic regression analysis in matched patients with and without air embolism with a ratio of 1:4.
A total of 27 cases of air embolism (median age, 67 years; range, 48-80 years; 24 men) were found with an incidence of 0.23% (27/11,691). Pulmonary vein injury during the procedures was identifiable on CT in 24 of 27 patients (88.9%), whereas it was 1.9% (2/108) for matched patients without air embolism The veins beyond the target lesion (70.8% [17/24]) were injured more frequently than the veins in the needle pathway before the target lesion (29.2% [7/24]). In univariable and multivariable analyses, pulmonary vein injury was associated with air embolism (odds ratio, 485.19; 95% confidence interval, 68.67-3428.19, p <.001).
Pulmonary vein injury was detected on CT and was associated with air embolism. Avoiding pulmonary vein injury with careful planning of the needle pathway on CT may reduce air embolism risk.
• Pulmonary vein injury during CT-guided biopsy was identifiable on CT in most of the patients (88.9% [24/27]). • The veins beyond the target lesion (70.8% [17/24]) were injured more frequently than the veins in the needle pathway before the target lesion (29.2% [7/24]). • Avoiding the distinguishable pulmonary vein along the pathway or shooting range of the needle on CT may reduce the air embolism risk.

PMID:
36006429
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 16
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement