[Development and validation of a 28-day death risk prediction model for sepsis-associated myocardial injury patients based on 48-hour echocardiographic parameters].

Created on 18 Nov 2026

Authors

Jing Xu, Wen Hu, Mu Zeng

Published in

Zhonghua wei zhong bing ji jiu yi xue. Volume 38. Issue 10. Pages 947-952.

Abstract

To develop and validate a 28-day death risk prediction model for patients with sepsis-associated myocardial injury based on 48-hour echocardiographic parameters.
A retrospective case-control study was conducted. A total of 120 patients with sepsis-associated myocardial injury admitted to Xiangya Hospital, Central South University, from April 2024 to April 2026 were enrolled. Demographic data (gender and age) and echocardiographic parameters measured within 48 hours of intensive care unit (ICU) admission were collected. These parameters included left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), right atrial diameter (RAD), right ventricular diameter (RVD), left ventricular ejection fraction (LVEF), tricuspid annular plane systolic excursion (TAPSE), the ratio of early diastolic transmitral flow velocity to early diastolic mitral annular velocity (E/e' ratio), left ventricular global longitudinal strain (LVGLS), and pericardial effusion. Univariate and multivariate Logistic regression analyses were performed to identify independent risk factors for 28-day death, and a nomogram prediction model was constructed. Internal validation was conducted using the Bootstrap resampling method (1 000 iterations). The receiver operator characteristic curve (ROC curve) was used to evaluate the discriminatory ability of the model. The calibration performance of the model was assessed through the calibration curve and the Hosmer-Lemeshow test. The decision curve was plotted to analyze the clinical practical value of the model.
All 120 patients were enrolled in the final analysis, of whom 87 survived for 28 days and 33 died, with a mortality of 27.5%. Compared with the survival group, patients in the non-survival group were older [years: 68 (64, 72) vs. 64 (58, 68), P<0.05], and exhibited significantly higher proportions of TAPSE<17 mm [58% (19/33) vs. 25% (22/87)], E/e' ratio>14 [64% (21/33) vs. 36% (31/87)], and LVGLS>-16% [64% (21/33) vs. 26% (23/87)], all P<0.05. The LVEF was also lower in the non-survival group as compared with the survival group (0.44±0.12 vs. 0.49±0.11, P=0.05). However, no statistically significant differences were observed between the two groups in terms of the proportion of males or other echocardiographic parameters (all P>0.05). Multivariable Logistic regression analysis revealed that advanced age, TAPSE<17 mm, E/e' ratio>14, and LVGLS>-16% were identified as independent risk factors for 28-day death in patients with sepsis-associated myocardial injury, while LVEF was not included in the final model. For each 1-year increase in age, the risk of 28-day death increased by 10.8% [odds ratio (OR)=1.076, 95% confidence interval (95%CI) was 1.019-1.136, P=0.009]. A 3.709-fold higher risk of 28-day death was observed in patients with TAPSE<17 mm compared with those with TAPSE≥17 mm (OR=3.709, 95%CI was 1.373-10.017, P=0.010). Patients with E/e' ratio>14 were shown to have a 3.027-fold higher risk of 28-day death than those with E/e' ratio≤14 (OR=3.027, 95%CI was 1.147-7.988, P=0.025). Moreover, a 4.924-fold higher risk of 28-day death was demonstrated in patients with LVGLS>-16% compared with those with LVGLS≤-16% (OR=4.924, 95%CI was 1.754-7.988, P=0.002). A nomogram for predicting 28-day death in patients with sepsis-associated myocardial injury was subsequently constructed based on the above four independent risk factors. ROC curve analysis showed that the area under the ROC curve (AUC) of the predictive model was 0.829 (95%CI was 0.743-0.905), and the internally validated AUC was 0.843 (95%CI was 0.753-0.917). Calibration curve showed good consistency between the predicted probabilities and the actual observed outcomes, and the Hosmer-Lemeshow goodness-of-fit test yielded a χ 2 value of 8.226 with 8 degrees of freedom (P=0.412), indicating good calibration of the model. Decision curve analysis (DCA) demonstrated that the model provided a positive net clinical benefit when the threshold probability ranged from 5% to 80%.
The predictive model constructed based on age and the echocardiographic parameters TAPSE, E/e' ratio, and LVGLS measured within 48 hours demonstrated good predictive performance for 28-day death risk in patients with sepsis-associated myocardial injury.

PMID:
43045526
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement