Non-phthalate plastic additives contamination from laboratory consumables: A quantitative assessment across sample preparation workflows.

Created on 18 Nov 2026

Authors

Raquel Capilla-Flores, Rosalía López-Ruiz, Roberto Romero-González, Antonia Garrido Frenich

Published in

Analytica chimica acta. Volume 1428. Pages 346452. Dec 22, 2026. Epub Oct 29, 2026.

Abstract

The growing interest in analyzing plastic additives (PAs) is driven by their environmental persistence and adverse health effects, demanding reliable trace-level quantification. However, laboratory-derived contamination during sample preparation remains poorly characterized across common consumables and extraction workflows. This study presents, to our knowledge, the first comprehensive and quantitative assessment of non-phthalate plastic additive (NPPA) contamination from laboratory consumables and reagents. Twenty-eight NPPAs were monitored in blank extracts obtained from centrifuge tubes, pipette tips, syringes, syringe filters, and extraction salts, using ethyl acetate (EtOAc) and acetonitrile (ACN) as solvents, analyzed by gas and liquid chromatography coupled to high-resolution mass spectrometry (GC-HRMS and LC-HRMS, respectively). The lack of quantitative information on NPPA contamination introduced by routine laboratory consumables hampers the reliability of trace-level plastic additive analysis.
Syringe-filter assemblies were identified as the dominant contamination source, with nylon membranes releasing up to 218.7 ng of total NPPAs in EtOAc, compared to 70.1 ng for polytetrafluoroethylene filters. Commercially pre-packaged QuEChERS salt kits showed substantially higher contamination than individually weighed salts, with 1-hydroxycyclohexyl phenyl ketone (HCPK) levels approximately 1840-fold greater. EtOAc extracts (GC-HRMS) showed higher NPPA contamination than ACN extracts (LC-HRMS) for most materials evaluated. Plastic-stored technical-grade acetone increased the NPPA background by approximately 13-fold compared to glass-stored LC-MS-grade acetone. At the workflow level, best- and worst-case scenarios differed by nearly one order of magnitude in GC-based workflows and by more than two orders of magnitude for QuEChERS-based LC workflows, demonstrating the strong influence of material selection on cumulative contamination.
This study provides the first quantitative assessment of NPPA contamination arising from routine laboratory consumables across complete sample-preparation workflows. The results identify critical contamination sources, establish practical mitigation strategies, and demonstrate that consumable selection can have a greater impact on NPPA background levels than the extraction workflow itself, thereby improving the reliability of trace-level plastic additive determinations.

PMID:
43045398
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement