Towards cross-instrument LIBS calibration for rare earth element analysis.

Created on 18 Nov 2026

Authors

Diana Capela, Tomás Lopes, Jakub Buday, Rafael Cavaco, Pavel Pořízka, Pedro A S Jorge, Jozef Kaiser, Nuno A Silva, Diana Guimarães

Published in

Analytica chimica acta. Volume 1428. Pages 346410. Dec 22, 2026. Epub Oct 26, 2026.

Abstract

Laser-Induced Breakdown Spectroscopy (LIBS) has emerged as a promising technique for rare earth elements (REEs) analysis, offering rapid, in situ, and multi-element detection capabilities. However, LIBS-based REE identification remains challenging due to spectral complexity, line overlap, matrix effects, and limited interlaboratory reproducibility. Instrument-dependent factors, including acquisition conditions and system configurations, often introduce significant variability in both spectral signatures and spatial distributions, hindering direct comparison across different platforms and limiting the transferability of analytical models and calibration strategies between platforms and limiting the transferability of analytical models and calibration strategies between instruments.
To address these limitations, this work proposes a comprehensive pipeline for interlaboratory LIBS analysis of REEs, integrating image registration, feature selection, and Cross-Instrument Calibration. A key component of the approach is the establishment of spatial correspondence between datasets, ensuring reliable point-to-point comparisons. An affine transform assisted by Mutual Information was used for this task. Additionally, feature selection strategies as Mutual Information and Regularization are explored to identify the most informative spectral features, enabling signal reconstruction using K-Nearest Neighbors and Ridge Regression while minimizing overfitting. The methodology is validated using REE-bearing samples analyzed with two distinct LIBS systems, with different spatial resolutions. Ridge Regression achieved MAE values between 0.030 and 0.035 and RMSE values between 0.049 and 0.056, with regularization-based feature selection providing a marginal improvement in quantitative performance.
The proposed approach demonstrates that spatial registration combined with spectral calibration transfer can mitigate instrument-dependent differences and facilitate the comparison of LIBS measurements acquired across different systems. This provides a framework for improving cross-system reproducibility and supports the broader use of LIBS for robust, scalable, and transferable REE characterization across instrumentation platforms.

PMID:
43045379
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 6
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement