Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Switchable-hydrophilicity pH-Responsive deep eutectic solvent-assisted microfluidic preconcentration for smartphone-based colorimetric determination of rifaximin.

Created on 18 Nov 2026

Authors

Narges Bastan, Tayyebeh Madrakian, Mazaher Ahmadi, Abbas Afkhami

Published in

Analytica chimica acta. Volume 1428. Pages 346465. Dec 22, 2026. Epub Oct 29, 2026.

Abstract

In this study, a novel microfluidic liquid-phase microextraction strategy based on a pH-switchable deep eutectic solvent (sDES) was coupled with smartphone-based digital image colorimetry (μF-sDES-LPME-DIC) for the determination of rifaximin (RIF). Among six candidate sDESs, thymol-decanoic acid (1:2) was selected based on its high extraction efficiency (89.13%) and reversible phase-switching behavior. Within the microfluidic platform, NaOH converted the hydrophobic sDES into a water-miscible form, whereas subsequent acidification with HCl restored its hydrophobic character, enabling phase separation without centrifugation or the addition of a dispersive solvent. Four key experimental variables were optimized using a Box-Behnken design, yielding optimal conditions of 140 μL sDES, a sDES injection rate of 20 μL min-1, a sample flow rate of 5 μL min-1, and concentrations of NaOH and HCl (5 M each). Under the optimized conditions, the method exhibited a bilinear calibration response over two linear concentration range of 0.5-5.0 μg mL-1 and 5.0- 50.0 μg mL-1, with limits of detection and quantification of 0.14 and 0.47 μg mL-1, respectively. The method was successfully applied to the determination of RIF in human blood plasma and wastewater samples. The AGREEprep, SPMS, and BAGI scores were 0.69, 7.26, and 67.5, respectively, indicating favorable performance in terms of sample preparation greenness, sustainability, and analytical applicability. Overall, the proposed platform integrates switchable-solvent extraction, microfluidic processing, and smartphone-assisted colorimetric detection into a simple and portable analytical workflow, offering a rapid, resource-efficient, and environmentally favorable approach to RIF determination.

PMID:
43045377
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 6
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement