Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test - a literature review.

Created on 18 Nov 2026

Authors

Karlijn Koops, Annenienke C van de Ven, Michiel N Kerstens, Judith Ma Emmen, Nienke R Biermasz, Annemieke C Heijboer, Jacquelien J Hillebrand

Published in

Journal of molecular endocrinology. Nov 18, 2026. Epub Nov 18, 2026.

Abstract

The high-dose ACTH stimulation test is used to assess adrenal insufficiency. Although the test has a rather simple design, many variables in pretest conditions, performing the test and cortisol methods impact the interpretation of the test result, for which rigid cut-offs were previously used. There is growing attention to standardized work-up and using well-standardized analytical methods and assay-specific cortisol cut-offs. There is less consensus on whether post-stimulation serum cortisol concentrations should be measured at 30 minutes (t30) or 60 minutes (t60) or both. Often the same cortisol cut-off is used for measurements at both time points, even though the continuous cortisol response in this time frame suggests using different cut-offs. We reviewed studies describing cortisol measurements at t30 and t60 during the high-dose AST and studied diagnostic accuracy. We noted that cortisol cut-offs should be specific to the assay used and, when using modern assays, lower than the original 500 or 550 nmol/L. When using a single cut-off for t30 and t60, measurements at the t60 time point showed higher specificity. However, when using time point-specific cortisol cut-offs, the specificity of cortisol measurements at t30 or t60 appeared comparable. In conclusion, serum cortisol measurements at t30 and t60 during the high-dose ACTH stimulation test seem equally accurate. A similar performance may be achieved using either time point alone, provided time point and assay-specific cut-offs are used. It should be noted, however, that the results of the high-dose ACTH stimulation test should always be interpreted within the clinical context.

PMID:
43049450
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 12
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement