Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats.

Created on 18 Nov 2026

Authors

Mehmet Nur Çetin, Yusuf Sinan Şirin, Doğukan Polat, Batuhan Neyse, Latif Emrah Yanmaz

Published in

Veterinary ophthalmology. Volume 30. Issue 1.

Abstract

Rebound tonometry is widely used for measuring intraocular pressure (IOP) in cats; however, differences in clinical tonometer measurement configuration may contribute to variability in recorded values. This prospective repeated-measures study compared IOP measurements obtained using horizontal and vertical Tonovet Plus clinical measurement configurations in 32 client-owned, systemically and ophthalmologically normal conscious cats. Intraocular pressure was measured in the right eye while the probe was directed toward the center of the cornea and positioned 4-8 mm from the corneal surface. The order of horizontal and vertical configurations was randomized for each cat. Measurements were obtained by one experienced veterinary ophthalmologist and a trained student operator group. In the primary linear mixed-effects analysis accounting for repeated measurements within cats, horizontal configuration was associated with an estimated 2.41-mmHg higher IOP than vertical configuration (β = 2.41 mmHg; 95% CI, 1.39-3.44; p < 0.001). The configuration-associated difference was also observed separately for the experienced instructor (mean difference, 2.81 mmHg; 95% CI, 1.91-3.71; p < 0.001) and across the trained student operator group (2.00 mmHg; 95% CI, 0.81-3.19; p = 0.002). These findings indicate that horizontal and vertical Tonovet Plus clinical measurement configurations may yield different IOP values in conscious cats. As configuration changes may affect instrument handling, restraint, head positioning, and animal responses, the difference cannot be attributed solely to tonometer orientation or mechanics. Consistent configuration is therefore recommended when comparing serial IOP measurements in cats. Further controlled studies are needed to distinguish mechanical, ergonomic, and other examination-related mechanisms.

PMID:
43049601
Bibliographic data and abstract were imported from PubMed on 18 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement