Authors
Omer Mesut Celebi, Gulsah Yildiz, Cemanur Aydinalp
Published in
Medical & biological engineering & computing. Nov 18, 2026. Epub Nov 18, 2026.
Abstract
Traditional iterative optimization methods are widely used in microwave hyperthermia to concentrate the specific absorption rate (SAR) within the tumor while minimizing undesired heating in healthy tissue. However, variations in treatment conditions require restarting the optimization process, leading to high computational cost and limiting real-time clinical applicability. In this two-dimensional (2D) proof-of-concept work, a gradient-based meta-learning (GML) model is proposed to rapidly optimize the feeding parameters of a fixed antenna system for SAR focusing in simplified microwave hyperthermia study. Model performance is evaluated using the target-to-body SAR ratio (TBR) and the undesired hot-spot-to-target quotient (HTQ). Increasing the number of training tasks improves convergence stability, with the best performance achieved using deterministic sampling (TBR = 11.31 ± 0.71, HTQ = 0.65 ± 0.09). The proposed GML improves TBR by 1.63 and 3.55, and reduces HTQ by 0.02 and 0.24, compared to the phase-only model and phase conjugation method, respectively. Furthermore, compared to Particle Swarm Optimization (PSO), GML achieves comparable focusing performance while reducing computation time from 45.59 s to 1.37 s. Furthermore, the proposed approach was analyzed using 2D central slices of four MRI-derived breast phantoms. Fully converged PSO achieved a higher mean TBR than GML (49.73 ± 14.02 versus 29.93 ± 6.35), whereas GML reduced the optimization time by approximately 35-fold and achieved a higher TBR than PSO under an equal-runtime constraint (RM-PSO) (29.93 ± 6.35 versus 25.89 ± 7.56). In the thermal analysis of representative samples from the four models, GML, fully converged PSO, and RM-PSO achieved comparable mean T90 values above 41[Formula: see text]C (41.10 ± 0.51[Formula: see text]C, 41.09 ± 0.47[Formula: see text]C, and 41.31 ± 0.45[Formula: see text]C, respectively). GML also yielded a lower mean maximum healthy-tissue temperature (42.56 ± 1.45[Formula: see text]C) than fully converged PSO (43.29 ± 1.11[Formula: see text]C) and RM-PSO (43.74 ± 0.38[Formula: see text]C). These results support GML as a computationally efficient approach for rapid antenna-feeding adaptation within the investigated fixed 2D configuration.
PMID:
43050094
Bibliographic data and abstract were imported from PubMed on 19 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 10
- Comments 0