Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Microenvironment-responsive biodegradable materials for bone repair: spatiotemporal control, evidence classes and translational readiness.

Created on 19 Nov 2026

Authors

Guotai Huang, Bowen Li, Chenxu Shang, Xingwei An, Yang Bai, Bin Zheng, Huining He

Published in

Journal of materials chemistry. B. Nov 19, 2026. Epub Nov 19, 2026.

Abstract

Bone repair outcomes are determined by interacting infectious, vascular, immune, mechanical and patient-specific factors, and by the surgical context in which an implant is placed. Within that multifactorial setting, one mismatch belongs specifically to the implant: a biodegradable device executes a course fixed at manufacture, whereas the defect it treats changes. Local acidity, elevated reactive oxygen species (ROS) and enzymatic remodelling signals are therefore used as design inputs, although directly matched clinical thresholds remain poorly established. This Review asks how far biodegradable materials can couple therapeutic action to those changing conditions, and what would have to be demonstrated before such coupling becomes clinically useful. Three analytical tools are used. Spatiotemporal control is the evaluation lens, assessed as temporal fidelity and spatial specificity. A hierarchical intelligence classification (HIC) describes control capability rather than quality: single-input responses (L1), logic-gated multi-input responses (L2), programmed sequential responses (L3), and a prospective closed-loop class (L4) to which no current biodegradable bone implant is assigned. A translational-readiness gate covers the requirements that are independent of responsiveness-biocompatibility, mechanical compatibility, degradation and clearance, sterilisation, manufacturing reproducibility and regulatory pathway-and constrains every level. Quantitative values are reported with their evidence class, distinguishing clinical measurements, large-animal and small-animal results, in vitro conditions and author-proposed design targets. We conclude that the limiting problems are threshold calibration against patient pathology, control error under coupled signals, and unmet foundational requirements, rather than insufficient response complexity.

PMID:
43055671
Bibliographic data and abstract were imported from PubMed on 19 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement