Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Image-Level Splitting Inflates Apparent Performance Through Repeated Patient-Level Variables in Breast Ultrasound AI: A Patient-Grouped Study of Intraductal Papilloma.

Created on 20 Nov 2026

Authors

Secil Gundogdu, Eda Elverici, Leman Gunbey Karabekmez, Pelin Zeynep Bekin Sarıkaya, Eren Camur, Emre Gundogdu, Izzet Selcuk Parlak

Published in

Journal of imaging informatics in medicine. Nov 19, 2026. Epub Nov 19, 2026.

Abstract

To quantify how image-level rather than patient-level fold assignment inflates the apparent performance of breast ultrasound models, using a clinical task without demonstrable discrimination as a negative control. This retrospective single-centre study included 250 women with intraductal papilloma (IDP; 553 B-mode images; 184 colour Doppler images in 144 patients), 47 (18.8%) with associated atypical ductal hyperplasia (ADH) or ductal carcinoma in situ (DCIS). Radiomics, clinical-variable, and deep-learning models were evaluated with patient-grouped nested fivefold cross-validation, permutation nulls, and repeated partitions. The same models were then evaluated under image-level fold assignment, and the source of inflation was examined with matching, perturbation, and synthetic-variable controls. Discrimination above chance was not demonstrated: patient-level AUCs were 0.490-0.563, every 95% confidence interval included 0.5, and no upper limit reached 0.70. Changing only fold assignment increased the radiomics-plus-clinical AUC from 0.506 to 0.788 (ΔAUC 0.282; patient-clustered 95% CI 0.209-0.351), and averaging predictions per patient did not remove the inflation (0.504 versus 0.800). Across 20 partitions, mean inflation was 0.363 for age plus lesion size, 0.226 for radiomics, and 0.109 for a B-mode network trained to fit its training data. Random variables held constant within each patient produced similar inflation (0.415), whereas variables varying across images produced none. In a cohort without demonstrable discrimination under patient-grouped validation, image-level fold assignment generated substantial apparent performance. Patient-constant variables acted as identifiers, and patient-level aggregation did not correct the leakage.

PMID:
43056015
Bibliographic data and abstract were imported from PubMed on 20 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 6
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement