Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Triclosan Surface Coating Inhibits Bacterial Attachment: In Vitro Assessment for Prosthetic Joint Infection Prevention.

Created on 20 Nov 2026

Authors

Julia L van Agtmaal, Laura C W Peeters, David Armbruster, Jan Geurts, Rajendra Kasinath, Jacobus J C Arts

Published in

BioMed research international. Volume 2026. Issue 1.

Abstract

Approximately 2% of primary and 30%-40% of revision arthroplasties lead to prosthetic joint infection (PJI). Biofilm formation and antimicrobial resistance decrease bacterial susceptibility to antibiotics. This study examined the use of the synthetic broad-spectrum antimicrobial agent triclosan (2, 2, 4 '-trichloro-2 '-hydroxyphenyl ether) to prevent bacterial attachment on titanium (Ti) and ultrahigh-molecular-weight polyethylene (UHMWPE) substrates without a carrier by vaporizing it in a reservoir. Triclosan loading on Ti and UHMWPE and release from Ti samples was assessed over 21 days. In vitro antimicrobial activity against S. aureus and E. coli was tested according to standards ISO 22196, ASTM E 2180-18, and JIS Z 2801 for regulatory compliance, followed by bacterial adhesion tests in suspension. Cell viability was assessed following ISO 10993-5 standards using WST-1 and LDH assays with L929 cells (ATCC cell line CCL 1, NCTC clone 929) in a static test on extract. The target loading of 0.15 mg/cm2 was achieved on Ti (0.15 mg/cm2), whereas UHMWPE reached 0.03 mg/cm2. The 21-day release test on Ti samples showed an initial burst of 0.05 mg/cm2 on Day 1. The cumulative release was 0.126 mg/cm2 (84% of the total dose), indicating continuous triclosan release and availability. Both antimicrobial tests and bacterial strains showed a reduction of 3.70-6.18 logs in bacterial count for the triclosan-coated samples compared with uncoated ones. Triclosan was more effective against S. aureus than E. coli. The Ti samples showed slightly higher reductions than UHMWPE. Triclosan exhibited low cell viability (4.1%-41.2%) and high cytotoxicity (up to 97.8%) across all tested extract concentrations. Although the triclosan coating demonstrated a significant bacteriostatic and bactericidal effect, results from static 2D cell viability assays raise concerns at this dose level. Further research using dynamic in vitro or in vivo systems is necessary to investigate the balance between the antibacterial efficacy and the toxic effects of triclosan.

PMID:
43062120
Bibliographic data and abstract were imported from PubMed on 20 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement