Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Bispecific Coiled-Coil Reporters Enable Rapid, Multiplexed Detection of Mycoplasma via Toehold Switch Sensors.

Created on 20 Nov 2026

Authors

Yudan Li, Nery R Arevalos, Amit Eshed, Shannon Newell, Carlye Frisch, N Rebecca Kang, Xiao Wang, David A Brafman, Alexander A Green

Published in

ACS synthetic biology. Volume 15. Issue 11. Pages 4645-4656. Nov 20, 2026.

Abstract

Cell-free synthetic biology offers a rapid prototyping environment for molecular diagnostics, yet the utility of these systems is often limited by the slow kinetics and restricted multiplexing capabilities of traditional protein reporters. Here, we report the BINOCULAR (BIspecific Novel Orthogonal Coiled-coil-Using LAteral flow Reporter) system based on supramolecular coiled-coil peptide conjugates that dramatically accelerates signal generation and enables robust multiplexing in cell-free transcription-translation reactions. Using BINOCULARs as toehold switch outputs, we achieve visible readout times of less than 5 min in lateral flow assays, achieving a ≥12-fold increase in speed compared to standard cell-free reporters like β-galactosidase or fluorescent proteins. To demonstrate the utility of this platform, we integrated the bispecific reporters with loop-mediated isothermal amplification and lateral flow assays for the detection of mycoplasma, a common adventitious agent in biomanufacturing. The integrated system demonstrates exceptional sensitivity, achieving a detection limit of 50 genomic copies/mL for mycoplasma and a mammalian internal control. Cell-free assay results were available within 5 min following a 20 min amplification step, and we successfully achieved the simultaneous detection of three distinct targets in a single reaction. Crucially, the platform maintains reliable performance in complex matrices and after lyophilization, making it more accessible for point-of-use applications. Our findings suggest that the modular BINOCULAR architecture can overcome current bottlenecks in cell-free sensing systems, providing a versatile and scalable framework for rapid, point-of-use screening across clinical and industrial applications.

PMID:
43061952
Bibliographic data and abstract were imported from PubMed on 20 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement