Authors
Suet Yi Kennis Ng, Yick Wing Ho, Ka Hei Jason Lok, Chi Yuen Harry Cheng
Published in
Medical dosimetry : official journal of the American Association of Medical Dosimetrists. Nov 20, 2026. Epub Nov 20, 2026.
Abstract
HyperArc stereotactic radiosurgery (SRS) for multiple brain metastases (MBM) uses cone beam computed tomography (CBCT) for pretreatment setup, and megavoltage (MV) portal imaging for intrafraction verification. At gantry 0°, MV portal imaging has limited sensitivity to anterior-posterior motion corresponding to treatment-couch vertical displacement as this motion is approximately parallel to the imaging beam axis. This study evaluated stereoscopic kV ExacTrac as a complementary verification method and quantified the dosimetric effect of simulated vertical setup offsets. A Sun Nuclear STEEV cranial phantom was shifted from ± 1 to ± 10 mm. Lateral and longitudinal shifts were evaluated at couch angles 0°, 45°, 90°, 270°, and 315°, while vertical shifts were evaluated at couch angles 0° and additionally at 270°. Shift measurements from ExacTrac, MV portal imaging, and CBCT were compared where geometrically available. In 19 patients with 53 lesions, clinical plans were recalculated with vertical isocenter offsets from ± 0.5 to ± 3.0 mm in 0.5 mm increments. Changes in Paddick conformity index (Paddick CI), homogeneity index (HI), gradient index (GI), and doses to organs at risk (OARs) were evaluated. PTV size and distance from isocenter were assessed using Spearman correlations and linear mixed-effects modelling. At couch 0°, mean ExacTrac-CBCT discrepancies were 0.017 ± 0.201 mm laterally, 0.080 ± 0.101 mm longitudinally, and 0.008 ± 0.130 mm vertically. MV portal imaging did not report the introduced treatment-couch vertical shifts. At the tested non-coplanar couch angle of 270°, ExacTrac identified the introduced vertical shifts while MV remained insensitive to this displacement at gantry 0°. Simulated 0.5 mm vertical offsets reduced Paddick CI by approximately 3%, while 3 mm offsets reduced conformity by more than 50% and increased HI. Smaller PTVs showed progressively greater conformity loss as shift magnitude increased (shift × log10 PTV interaction β = -0.071, 95% CI -0.078 to -0.064, p < 0.001), whereas the shift × distance interaction was not significant (p = 0.919). OAR dose changes were small at the cohort level, generally less than 0.1 Gy. Under controlled phantom conditions, stereoscopic kV imaging provided additional sensitivity to treatment-couch vertical displacement relative to MV portal imaging at gantry 0°. Dosimetric simulations showed a size-dependent reduction in target conformity with increasing vertical offset. Therefore, ExacTrac may serve as a complementary intrafraction verification option for HyperArc, particularly during non-coplanar delivery, while CBCT remains important for volumetric anatomical assessment. Patient-based validation is required to establish minimum clinically detectable shifts and clinical outcome benefit.
PMID:
43064640
Bibliographic data and abstract were imported from PubMed on 21 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 6
- Comments 0