Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis.

Created on 21 Nov 2026

Authors

Dr Sundar Chidambaram, Dr P Manokar, Dr Jebaraj, Dr Maheshbabu P, Dr Mahadevan V, Dr Deepchand Raja, Dr Nitheshkumar, Dr Surendhar G, Dr Selvaprakash E, Dr Nagendraboopathy Senguttuvan, Dr Ashish H Shah, Dr Vaikom S Mahadevan

Published in

Indian heart journal. Nov 20, 2026. Epub Nov 20, 2026.

Abstract

The comparative performance of balloon-expandable (BEV) and self-expanding (SEV) transcatheter heart valves in bicuspid aortic valve (BAV) stenosis remains uncertain.
We systematically reviewed contemporary BAV-TAVR literature published from 2015 to 2025. The broader qualitative evidence map comprised 69 reports, including device-specific and comparative cohorts; however, only studies with extractable arm-level BEV-versus-SEV data were eligible for quantitative comparative pooling.
Three head-to-head cohorts contributed to early/30-day device success (BEV 302/353; SEV 160/181). The pooled RR for SEV versus BEV was 1.03 (95% CI 0.96-1.09; I2=0%). Two cohorts contributed to 30-day permanent pacemaker implantation (PPI), showing a numerically higher but non-significant risk with SEV (RR 2.01; 95% CI 0.93-4.37; I2=0%). Only one study provided compatible 30-day arm-level data for moderate-or-greater paravalvular leak (PVL), precluding pooling. Adjusted and single-arm observational evidence suggested possible platform-specific differences in hemodynamics, PVL and conduction outcomes, but these data were not interpreted as evidence of comparative equivalence or superiority.
Available head-to-head evidence does not demonstrate a clear difference in early device success between contemporary BEV and SEV in BAV, but the evidence is sparse, predominantly observational and imprecise. The findings should not be interpreted as proof of equivalence. Prospective comparative studies with standardized BAV phenotyping are required.

PMID:
43064192
Bibliographic data and abstract were imported from PubMed on 21 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement