Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Simple and easy to build mechanical ventilator for pandemic health crises in resource-limited areas.

Created on 21 Nov 2026

Authors

Ramon Farré, Raffaella Salama, Miguel A Rodríguez-Lázaro, Kasra Kiarostami, Laia Fernández-Barat, Viviane De Cassia Oliveira, Antoni Torres, Núria Farré, Anh Tuan Dinh-Xuan, David Gozal, Jorge Otero

Published in

Frontiers in public health. Volume 14. Pages 1855214. Epub Nov 06, 2026.

Abstract

The COVID-19 pandemic exposed critical shortages of mechanical ventilators, particularly in low-resource settings. Disruptions in global supply chains and dependence on specialized components highlighted the need for scalable, locally manufacturing alternatives for emergency respiratory support.
To describe and evaluate a simplified mechanical ventilator with minimal supply-chain dependence, assembled from widely available automotive and simple hardware components, and intended as a last-resort solution.
The ventilator is based on a reciprocating air pump driven by an automotive windshield wiper motor coupled to parallel shaft bellows and readily assembled passive membrane valves, only requiring materials available from standard hardware retailers, minimal tools, and basic manual skills. Ventilator performance was assessed through bench testing using a patient model simulating severe lung disease in an adult (R = 20 cmH₂O·s/L, C = 15 mL/cmH₂O) and pediatric (R = 50 cmH₂O·s/L, C = 10 mL/cmH₂O) patients. Realistic proof of concept was performed in four mechanically ventilated 50-kg healthy pigs.
According to the bench test, the device delivered tidal volumes up to 600 mL and respiratory rates up to 45 breaths/min with PEEP up to 10 cmH₂O, covering most pediatric and adult ventilation ranges. The in vivo proof-of-concept showed that the ventilator maintained arterial blood gases within the targeted range. Technical details for ventilator construction are provided in an open-source video tutorial.
Notwithstanding its limitations, this low-cost ventilator demonstrated adequate performance as a prototype. Although not a substitute for commercial intensive care ventilators, its simplicity, autonomy, and low dependence from fragile supply chains provides an approach towards life-saving options in resource-constrained emergency scenarios.

PMID:
43065513
Bibliographic data and abstract were imported from PubMed on 21 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement