Authors
Ajuan Gong, Wanjin Fu, Wenjing Li, Xiaoqun Xu, Xiaomin Huang, Nuojin Wang, Yue Wang, Tianrong Pan, Yijun Du
Published in
Frontiers in endocrinology. Volume 17. Pages 1944475. Epub Nov 06, 2026.
Abstract
To assess whether a DFUC2022-derived soft ulcer-region prior improves four-class infection/ischaemia label prediction in ulcer-centred DFUC2021 patches, using comparators matched for classifier architecture or base-model outputs.
We analysed 5, 955 labelled patches using five fixed image-similarity-grouped outer folds and five training seeds. CNN checkpoint selection and stacker fitting and selection excluded each outer evaluation fold. Three incremental comparisons assessed Full lesion-prior transfer (LPT) against an architecture-matched neutral-prior control, reliability-aware LPT (RA-LPT) against its output-only stack, and strong RGB stacks with versus without explicit prior features. Pointwise 95% confidence intervals and approximate two-sided p values were obtained from 5, 000 paired crossed seed × similarity-group bootstrap resamples; p values were Holm-adjusted across the three comparisons.
Full LPT achieved Macro-F1 of 0.8921 ± 0.0059 versus 0.8777 ± 0.0085 for neutral Full LPT (mean ± sample SD across seeds). The mean paired difference was +0.0144 (95% CI, + 0.0048 to +0.0244; Holm-adjusted approximate p = 0.0132), positive in all five seeds. RA-LPT achieved Macro-F1 of 0.9181 ± 0.0038 versus 0.9206 ± 0.0028 for its corresponding output-only stack, without demonstrating an incremental improvement (difference, -0.0026; 95% CI, -0.0066 to +0.0012; adjusted p = 0.3079). Adding explicit prior features to the strong RGB stack also did not demonstrate an improvement in Macro-F1 (-0.0016; 95% CI, -0.0057 to +0.0025; adjusted p = 0.4223). The strong RGB stack achieved 0.9370 ± 0.0050, above Full LPT. In a later exploratory training-size analysis, Full LPT and its neutral control improved with increasing labelled-training budgets; mean Full LPT-minus-neutral Macro-F1 differences were positive at all four budgets, but all pointwise 95% confidence intervals included zero.
In the main five-seed evaluation, sample-specific prior information improved Full LPT relative to its architecture-matched neutral control. Its incremental value was comparator-dependent: additional explicit prior features showed no confirmed improvement beyond the evaluated model-output stacks. Patient identifiers and target-domain lesion masks were unavailable; these internal development findings require patient-linked, multicentre external validation before clinical use.
PMID:
43065460
Bibliographic data and abstract were imported from PubMed on 21 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 9