Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Titanium miniplate fixation of complex carapacial and plastral fractures in a young red-footed tortoise (Chelonoidis carbonarius): A case report with three-year follow-up.

Created on 21 Nov 2026

Authors

Rodolfo Olinto Rotoli Garcia Oliveira, Bruno Watanabe Minto, Jorge Luis Ferreira, Antonio Araujo Leite, Arnaldo Jacinto da Silva Segundo

Published in

Veterinary and animal science. Volume 34. Pages 100941. Epub Nov 08, 2026.

Abstract

Traumatic shell fractures in chelonians may involve the carapace, plastron, and underlying osseous structures, resulting in mechanical instability and potentially severe associated injuries. Although several shell repair techniques have been described, information regarding rigid titanium plate fixation and its long-term outcome in growing red-footed tortoises (Chelonoidis carbonarius) is limited.
A young, growing red-footed tortoise (C. carbonarius) of unknown age and weighing approximately 400 g was presented one day after accidental vehicular trauma with complex fractures involving both the carapace and plastron. Clinical and radiographic assessment demonstrated substantial displacement and mechanical instability. Surgical stabilization was performed using titanium straight and reconstruction miniplates, which were sectioned and contoured intraoperatively to conform to the three-dimensional geometry of the shell. Immediate postoperative radiography documented fracture reduction and implant positioning. At approximately one year after surgery, clinical follow-up demonstrated maintenance of shell integrity, substantial continued growth, and persistence of the fixation implants. During the subsequent follow-up period, the owner reported progressive loss of some plate segments as the tortoise contacted the implants against objects and obstacles within its enclosure, without reported clinical complications. At approximately three years, substantial additional shell growth was evident, with one reconstruction plate segment remaining in place and a localized alteration in shell contour adjacent to the region of the retained hardware. Long-term radiographic follow-up was unavailable; therefore, a causal relationship between the retained implant and the contour alteration could not be established.
Contoured titanium miniplates provided rigid stabilization of complex carapacial and plastral fractures in this young red-footed tortoise. The three-year clinical outcome supports the feasibility of this fixation strategy while highlighting the importance of long-term monitoring and reassessment of retained rigid implants in actively growing chelonians.

PMID:
43065346
Bibliographic data and abstract were imported from PubMed on 21 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement