Authors
Kallista Zhuang, Shinji Kakihara, Anna M Busza, Gavin Robertson, Ivy Zhu, Amani A Fawzi
Published in
Ophthalmology science. Volume 6. Issue 12. Pages 101435. Epub Oct 12, 2026.
Abstract
To determine whether cell density-weighted retinal nonperfusion (RNP), derived by mapping ultra-widefield fluorescein angiography-defined nonperfusion to rod, cone, and retinal ganglion cell topography, is associated with low-luminance visual acuity (LLVA) in eyes with diabetic retinopathy (DR) and provides incremental explanatory value beyond conventional area-based RNP.
Cross-sectional observational study.
213 eyes from 140 adults with diabetes across the spectrum of DR severity.
Retinal nonperfusion was manually delineated on ultra-widefield fluorescein angiography images. Using normative retinal cell density maps, rod, cone, and retinal ganglion cell affected ratios (rod affected ratio [Rod-AR], cone affected ratio [Cone-AR], and retinal ganglion cell affected ratio [RGC-AR]) were calculated within the ETDRS 7-field region. Low-luminance visual acuity was measured using ETDRS letter scores with a 2.0-log unit neutral density filter. Linear mixed-effects models with a subject-specific random intercept accounted for intereye correlation. Models evaluating LLVA were adjusted for age, sex, diabetes duration, hemoglobin A1c, lens status, and hypertension. Rod affected ratio, Cone-AR, RGC-AR, and conventional RNP were each added separately to the clinical base model. Models incorporating RNP or Rod-AR were compared, and the incremental explanatory value of adding Rod-AR to the model containing RNP was evaluated.
Statistical associations between Rod-AR, Cone-AR, and RGC-AR and LLVA letter score and model explanatory performance.
Mean LLVA was 76.3 ± 6.9 letters. Retinal nonperfusion and affected cell ratios generally increased with greater DR severity. In separate adjusted models, greater Rod-AR was associated with worse LLVA (β, -1.72; 95% confidence interval, -2.55 to -0.89; P < 0.001), as was greater Cone-AR (β, -1.51; 95% confidence interval, -2.34 to -0.67; P < 0.001). Retinal ganglion cell affected ratio was not associated with LLVA (P = 0.747). Models adding RNP or Rod-AR showed similar performance (Akaike information criterion, 1341.1 vs. 1340.9; marginal R2, 0.377 vs. 0.378). Adding Rod-AR to the RNP model did not significantly improve explanatory performance (likelihood ratio test P = 0.607).
Greater Rod-AR and Cone-AR were associated with worse LLVA after adjustment for clinical covariates. However, Rod-AR did not demonstrate incremental explanatory value beyond conventional RNP. These findings support an association with LLVA, but not an explanatory advantage of rod-density weighting over area-based nonperfusion.
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PMID:
43067915
Bibliographic data and abstract were imported from PubMed on 22 Nov 2026.