Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Ultrasonographic formulas for pleural fluid volume estimation in adults: A scoping review.

Created on 23 Nov 2026

Authors

Małgorzata Leciejewska, Juliusz Bokiej, Tomasz Pawlica, Aleksander Bokiej

Published in

The ultrasound journal. Volume 18. Issue 1. Pages 18731. Nov 20, 2026. Epub Nov 20, 2026.

Abstract

To systematically map the methodological heterogeneity, reliability, and clinical utility of ultrasonographic formulas for estimating pleural fluid volume in adults.
This scoping review was conducted according to PRISMA-ScR guidelines. A comprehensive search of PubMed was performed (last update: March 2026), supplemented by manual citation tracking. We included human studies proposing or validating quantitative pleural fluid volume estimation formulas. Data were charted regarding study design, reference standards, measurement techniques, and statistical performance. No formal protocol was registered.
Twelve primary studies describing 15 distinct ultrasonographic formulas were included. The identified formulas ranged from simple linear measurements to advanced multiplanar summation techniques. We observed substantial methodological heterogeneity in reference standards (CT vs. thoracentesis), procedural timing, and statistical reporting. Multiplanar and CT-validated approaches demonstrated superior accuracy with lower proportional error (1-8%) compared to single-parameter formulas (6-24%). However, widespread inconsistency in reporting bias and limits of agreement complicates direct comparison. Mechanical ventilation, patient positioning, and respiratory phase emerged as significant but inconsistently documented sources of variability. Estimation errors of 100-250 mL were common, indicating limited precision for individual patient management.
Ultrasonographic estimation of pleural fluid volume is clinically feasible but constrained by significant methodological heterogeneity and a lack of standardized performance metrics. While multiplanar models offer higher precision, their clinical implementation requires further validation. Ultrasound-derived volumes should serve as a complementary diagnostic tool, and future research must prioritize geometry-aware models and standardized reporting to bridge the gap between anatomical measurement and clinical decision-making.

PMID:
43070361
Bibliographic data and abstract were imported from PubMed on 23 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 12
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement