Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Beyond clear aligners: A lifecycle framework for micro- and nanoplastic exposure in orthodontics: A narrative review.

Created on 24 Nov 2026

Authors

Ezgi Cansu Firinciogullari, Nikhillesh Vaiid, Sumit Yadav, Vaibhav Gandhi

Published in

Journal of the World federation of orthodontists. Nov 23, 2026. Epub Nov 23, 2026.

Abstract

Micro and nanoplastics have emerged as important concerns across dental biomaterials, toxicology, environmental health, and exposure science. Orthodontics is particularly relevant because contemporary treatment relies heavily on polymer‑based appliances and auxiliaries used in active, mechanically dynamic systems, often in young patients. These include clear aligners, retainers, elastomeric ligatures, power chains, intermaxillary elastics, orthodontic adhesives, composite attachments, removable appliances, and directly printed orthodontic devices. Current evidence shows measurable microscale particle release from clear aligners when exposed to artificial saliva, friction, cyclic loading, and simulated oral aging. However, aligners are not a uniform material class: thermoformed, multilayer, polyurethane-based, PETG-based, and direct-printed systems differ in polymer chemistry, manufacturing route, surface architecture, curing dependency, water sorption, residual defect profiles, and degradation behavior. Orthodontic elastomerics, adhesives, composite attachments, bonded retainers, and debonding procedures also represent plausible but under-characterized sources of particulate and chemical exposure. This review synthesizes evidence on micro and nanoplastic exposure in orthodontics within a dedicated lifecycle-based framework organized across five interrelated dimensions: 1) material- and workflow-dependent release; 2) exposure frequency and duration; 3) patient- and use-related modifiers; 4) biological interface outcomes; and 5) postuse environmental fate. Particular emphasis is placed on thermoformed aligners, direct‑print resins, retainers, removable appliances, aligner-attachment interfaces, elastomeric auxiliaries, adhesives, incomplete curing, bisphenol‑ and methacrylate‑related leachates, and environmental persistence. We highlight that the field remains methodologically immature and that particle detection should not be equated with clinical disease. A structured orthodontic framework is needed to distinguish documented microscale release from inferred nanoscale risk, to interrogate workflow‑dependent biocompatibility, and to guide safer material design, clinical protocols, waste collection, recycling strategies, and future exposure studies.

PMID:
43073142
Bibliographic data and abstract were imported from PubMed on 24 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement