Authors
Enrico Michele Salamone, Eleonora Grande, Augusto Di Castelnuovo, Giancarlo Di Gennaro, Marcello Bartolo, Diego Centonze, Marco Ciavarro, Andrea Bartolo
Published in
AJNR. American journal of neuroradiology. Nov 23, 2026. Epub Nov 23, 2026.
Abstract
Arterial spin-labeling (ASL) MR imaging is a noninvasive perfusion technique used in presurgical evaluation of focal epilepsy. A 2021 meta-analysis assessed its accuracy for identifying perfusion abnormalities concordant with the epileptogenic zone (EZ) but predated later studies and partly derived specificity from healthy-control true negatives. We re-estimated the diagnostic accuracy of ASL for EZ-concordant perfusion abnormalities with explicit handling of true negatives, and tested whether current data permit a quantitative estimate of the relationship between ASL findings and postsurgical seizure freedom.
Following PRISMA 2020 and PRISMA-DTA, we searched PubMed, Embase, Cochrane CENTRAL, and Scopus from inception to June 2026 for English-language primary studies (≥10 patients) of ASL for EZ localization or surgical-outcome evaluation in focal epilepsy. Random-effects models estimated pooled sensitivity (logit; primary), an exploratory specificity, a logit concordance/detection proportion, and a Freeman-Tukey seizure-free proportion. Because true negatives were absent by design, a joint bivariate/HSROC model was not estimable. Risk of bias used QUADAS-2 and QUIPS; certainty of evidence used a DTA-adapted GRADE approach.
Fifteen studies were included. The primary analysis (8 studies, 160 patients) yielded a pooled ASL sensitivity for EZ-concordant abnormalities of 0.73 (95% CI, 0.65-0.80; I2 = 0.0%). The concordance/detection proportion was 0.78 (95% CI, 0.62-0.89; 4 studies), and exploratory specificity 0.37 (95% CI, 0.13-0.71; 5 studies). In the surgical-outcome arm, the pooled seizure-free proportion (Engel I/ILAE 1) was 0.68 (95% CI, 0.58-0.77; 4 studies) and 0.71 (95% CI, 0.56-0.84) in a stricter analysis. Critically, a pooled odds ratio for seizure freedom in ASL-concordant versus ASL-discordant resections could not be computed: the required cross-tabulation was reported in no study.
ASL has moderate, stable sensitivity for identifying perfusion abnormalities concordant with the anatomo-electro-clinically defined EZ, whereas specificity is not estimable from current single-group designs. ASL-linked surgical cohorts achieve seizure freedom in two-thirds of operated patients, but whether ASL-resection concordance predicts seizure freedom is unquantifiable: a reporting gap, not a null result. Until outcome is reported stratified by ASL-resection concordance, ASL should be used as a localizing adjunct, not a prognostic marker.
PMID:
43073028
Bibliographic data and abstract were imported from PubMed on 24 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 6
- Comments 0