Three-Dimensional T2-Weighted Variable Flip-Angle Turbo Spin Echo for Cervical Spine MRI at 0.55 T: A Feasibility Study.

Created on 24 Nov 2026

Authors

Bochao Li, Jay Acharya, Jordan S Gross, Steven Y Cen, Brian A Hargreaves, Krishna S Nayak

Published in

Academic radiology. Nov 23, 2026. Epub Nov 23, 2026.

Abstract

To evaluate the feasibility of three-dimensional T2-weighted sampling perfection with application-optimized contrasts using different flip angle evolutions (SPACE) for cervical spine magnetic resonance imaging (MRI) at 0.55 T and to preliminarily compare image quality with conventional two-dimensional T2-weighted turbo spin echo (TSE) in healthy volunteers and post-anterior cervical discectomy and fusion (ACDF) subjects.
Five healthy volunteers (26.6 ± 2.9 years) and five post-ACDF subjects with titanium implants (63.6 ± 7.2 years) underwent cervical spine MRI at 0.55 T using sagittal TSE, axial TSE, and sagittal SPACE. Quantitative analysis included signal-to-noise ratio (SNR) efficiency and cerebrospinal fluid (CSF)-to-spinal cord (SC) contrast-to-noise ratio (CNR) efficiency. Two board-certified radiologists independently evaluated perceived SNR, CSF pulsation artifacts, motion artifacts, visualization of ten anatomical structures, and metal artifact severity using a 5-point Likert scale. Quantitative sequence comparisons were performed using exact paired Wilcoxon signed-rank tests at the subject level. Qualitative 5-point scores were analyzed separately by cohort and category using linear mixed-effects models that accounted for subject and reader clustering.
3D SPACE demonstrated higher SNR efficiency than 2D TSE for both CSF and SC in both cohorts. CSF-SC CNR efficiency was higher with SPACE. In healthy subjects, 3D SPACE received higher reader scores for intraspinal nerve root visualization and CSF pulsation artifact reduction. In post-ACDF subjects, 3D SPACE received higher reader scores for nerve root visualization, whereas metal-artifact scores and other qualitative metrics did not show clear sequence-related differences.
3D SPACE at 0.55 T is feasible for cervical spine MRI in healthy subjects and post-ACDF subjects with titanium instrumentation. Although diagnostic performance was not evaluated, the preliminary findings suggest potential advantages of SPACE, including higher SNR/CNR efficiency, improved CSF signal homogeneity with reduced CSF pulsation artifacts, and improved nerve root visualization, supporting further evaluation.

PMID:
43073124
Bibliographic data and abstract were imported from PubMed on 24 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 9
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement