Abstract

Talar fractures are associated with high complication rates, and existing internal-fixation devices often exhibit inadequate mechanical strength and suboptimal anatomical fit. This study aimed to design a novel Micro-Anatomical Universal Locking Plate (MAULP) for talus fractures and evaluate its biomechanical performance via mechanical testing and finite element analysis (FEA).
The MAULP was pre-contoured based on CT data from 30 Chinese male tali and manufactured from Ti-6Al-4 V alloy. Fifteen synthetic talus fracture models were randomly assigned to three fixation groups (n = 5 each): Group A (two cannulated screws), Group B (MAULP alone), and Group C (MAULP plus one cannulated screw). Constructs underwent cyclic loading (400 N, 0.67 Hz, 20,000 cycles) followed by static loading. Interfragmentary displacement was recorded. FEA was performed under identical conditions. Three cadaveric tali (one per group) provided qualitative validation. One-way ANOVA was used for statistical analysis.
Pre-loading fracture gaps showed no significant differences among groups (p > 0.05). After cyclic loading, Group A exhibited significantly greater displacement (1.759 ± 0.042 mm) than Group B (1.359 ± 0.037 mm) and Group C (1.354 ± 0.042 mm) (both p < 0.05), with no significant difference between B and C (p > 0.05). Cadaveric trends paralleled synthetic models. FEA predictions correlated well with experiments (relative errors: 7.4%-7.8%), with the plate bearing higher stress (~0.3 MPa) than the talus (~0.1 MPa).
The MAULP, with or without an additional cannulated screw, provides significantly superior biomechanical stability compared to cannulated screws alone in a talar neck fracture model. Its anatomical design offers a promising fixation option, particularly for fractures requiring enhanced stability. Clinical studies are needed to confirm these findings.

PMID:
43073088
Bibliographic data and abstract were imported from PubMed on 24 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement