Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Calibration set reduction by iterative alternating reduction of predictive variables and calibration samples subsets.

Created on 24 Nov 2026

Authors

Jan P M Andries, Yvan Vander Heyden

Published in

Analytica chimica acta. Volume 1429. Pages 346468. Jan 01, 2027. Epub Oct 29, 2026.

Abstract

In this study, a new method for the reduction of calibration sets is proposed and evaluated. First, a global Partial Least Squares (PLS) model is developed with the original calibration set. Then, iteratively and sequentially, predictive variables and calibration subsets are reduced. In the loops of the new method, both the number of variables and samples gradually decrease. Predictive variables are reduced by the application of the Final Complexity Adapted Models (FCAM) method, using the significance (SIG) of the PLS coefficients, denoted as FCAM-SIG. Calibration subsets are reduced by the selection of the best fitting calibration samples which have an optimally predictive ability. The best fitting calibration subsets are called optimally predictive calibration subsets (OPCS). The OPCS are representative for the original global calibration model, and result in models with a similar predictivity. The newly proposed method, called alternating OPCS, is denoted as Alt-OPCS. The performance of the Alt-OPCS method is tested with four data sets from different sources, resulting in 12 X-y combinations. The X-profiles consist of either simulated data, NIR spectra, and molecular descriptors used to build Quantitative Structure-Retention Relationship (QSRR) models for reversed-phase liquid chromatography (RPLC) retention modelling. The predictive abilities of the obtained Alt-OPCS models are good and not significantly lower than those of the models obtained in one step, after FCAM-SIG variable selection and OPCS sample selection, by the recently published OPCS method, to which further is referred as the 1-step OPCS method. The selective ability of the Alt-OPCS method is significantly better than that of the 1-step OPCS method. Both the numbers of samples and of the variables from the Alt-OPCS method are significantly lower than those from the 1-step OPCS method. The selected variables have a chemical meaning. An advantage of the Alt-OPCS method is that no outliers are included in the calibration subsets because only the best fitting samples are selected. The application of the Alt-OPCS method may be advantageous in cases where small numbers of calibration samples are beneficial, for example for the transfer of calibration models between instruments.

PMID:
43072927
Bibliographic data and abstract were imported from PubMed on 24 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement