Authors
S Pellacani, R Barbieri, B Benedetti, J Camacho, M Cocchi, C Durante, G Perra, C Scopetani, L Strani
Published in
Analytica chimica acta. Volume 1429. Pages 346467. Jan 01, 2027. Epub Oct 29, 2026.
Abstract
Non-target screening by LC-HRMS is increasingly used to investigate complex environmental samples, but its reliability strongly depends on data-processing parameters and on the ability to distinguish chemically meaningful signals from noise, blank-related features and poorly resolved chromatographic contributions. In wastewater studies, an additional challenge is the interpretation of high-dimensional chemical profiles according to structured experimental factors, such as sampling point, sampling day and their interaction. In this work, a chemically guided Region of Interest - Multivariate Curve Resolution (ROIMCR) workflow was developed for wastewater LC-HRMS data, integrating ROI threshold selection, blank filtering, target-standard detection, MCR model evaluation, reliability-based component classification and variable-selection ANOVA simultaneous Component Analysis (vASCA)-based interpretation.
ROI extraction was optimized independently for LC-HRMS positive and negative HESI datasets by combining the percentage of ROIs retained after blank filtering (%GoodROI) with the detection of target compounds in a multi-standard mixture. MCR models with 200 and 100 components were selected as the best compromise between explained variance, lack of fit, convergence and chemical interpretability. After classification of resolved components according to chromatographic and spectral reliability, 203 Class A and Class B components were retained. QC-based filtering produced a final matrix of 190 repeatable variables. Putative annotation was performed by combining accurate mass, retention time and MS/MS spectral information. Overall, 86 compounds were annotated in positive mode and 23 in negative mode, spanning pharmaceuticals and bioactive compounds, personal care products, industrial contaminants and agricultural contaminants. The final data matrix was analysed by PCA and vASCA. Sampling point, sampling day and their interaction significantly affected the wastewater chemical profile.
The proposed workflow provides a chemically guided strategy for LC-HRMS non-target screening, shifting ROIMCR optimization from a mainly numerical fitting problem to a chemically constrained decision process. This improves the reliability of components retained for annotation and multivariate interpretation in complex wastewater datasets.
PMID: