Authors
Liyuan Chen, Sepeadeh Radpour, Michael Dohopolski, David Sher, Jing Wang
Published in
JCO clinical cancer informatics. Volume 10. Issue 4. Pages e2600090. Epub Nov 25, 2026.
Abstract
Accurate identification of malignant lymph nodes (LNs) is critical for guiding radiation therapy in head and neck squamous cell carcinoma (HNSCC). We developed an artificial intelligence (AI) model using computed tomography (CT) alone to predict LN malignancy and quantify predictive uncertainty to support a prospective randomized trial of involved nodal radiotherapy.
We analyzed 1,389 contoured LNs from 192 patients with HNSCC who underwent neck dissection, with pathologic status serving as ground truth. The data set was partitioned at the patient level using a fivefold cross-validation strategy (80% training/validation, 20% held-out testing per fold). The proposed AI model integrates outputs from a Spatially Aware-Support Vector Machine (SA-SVM)-Radiomics model and a Convolutional Neural Network model. Uncertainty of the malignancy prediction was quantified for each LN using an entropy calculation. The model's performance was evaluated using sensitivity, specificity, accuracy, and area under the receiver operating characteristic (AUC) curve.
The proposed CT-only AI model, selected based on the best validation performance during cross-validation, achieved strong performance on the testing set of 272 LNs. For all nodes, it achieved a sensitivity of 0.98 (95% CI, 0.944 to 1.000), specificity of 0.82 (95% CI, 0.761 to 0.866), accuracy of 0.85 (95% CI, 0.809 to 0.893), and AUC of 0.98 (95% CI, 0.958 to 0.990). For LNs < 17 mm in diameter (237 nodes), performance was shown as 0.97 (95% CI, 0.877 to 1.000) sensitivity, 0.82 (95% CI, 0.769 to 0.873) specificity, 0.84 (95% CI, 0.793 to 0.886) accuracy, and 0.96 (95% CI, 0.929 to 0.982) AUC. Uncertainty analysis showed higher accuracy for predictions with lower entropy: in cases with entropy <6.55 (n = 184), the model achieved 0.99 AUC, 0.98 sensitivity, and 0.88 specificity.
This CT-only model demonstrated high internal performance for LN malignancy prediction and provides uncertainty estimates that can identify cases requiring additional clinical review. Prospective and external validation are needed to assess generalizability and clinical utility.
PMID:
43084813
Bibliographic data and abstract were imported from PubMed on 26 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 11
- Comments 0