Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Quantitative comparison of SPECT- and PET- based methods for treatment planning and dosimetry in Y-90 radioembolisation therapy.

Created on 26 Nov 2026

Authors

Andrew Chacon, Aurora Poon, Wesley Ng, Sylvia J Gong, Andrew M Scott, Graeme J O'Keefe

Published in

Physical and engineering sciences in medicine. Nov 25, 2026. Epub Nov 25, 2026.

Abstract

Quantitative post-therapy imaging is essential for verifying administered activity and assessing dose distribution following Y-90 radioembolisation. This study compared large energy acceptance window Y-90 SPECT and PET for estimating implanted activity relative to the standard SIRTEX vial calibration method and evaluated their equivalence dosimetry. The retrospective Y-90 SPECT were acquired using protocols optimised for qualitative rather than quantitative imaging. The predictive accuracy of Tc-99​m MAA SPECT and compartmental models for pre-therapy dosimetry estimation was also investigated. A cohort of 28 patients treated with Y-90 resin microspheres underwent pre-therapy Tc-99​m MAA SPECT and post-therapy Y-90 SPECT and PET. The regional doses (tumour, perfused liver, and lungs) were calculated using the local deposition model. Equivalence between methods was assessed using the two one-sided tests. The Y-90 SPECT and PET measurements of implanted activity was on average -3 % ± 12 % and -5 % ± 13 %, of the SIRTEX calculated method. Tumoural doses derived from Y-90 SPECT and PET were statistically equal and equivalent (mean difference -1 %, SD ± 14 %), and perfused liver doses were equivalent within ±5 Gy (mean difference 2 Gy, SD 13 Gy). Despite statistical equivalence, a 14-42% variability in individual measurements remained. Tc-99​m MAA SPECT-predicted tumour doses showed closer agreement with PET doses than the partition model (4% vs 6%), while perfused liver and lung predictions were comparable. Although PET remains the current clinical reference standard, Y-90 SPECT provides clinically acceptable equivalence where PET is not available while supporting post-therapy verification and retrospective dosimetric analyses.

PMID:
43084222
Bibliographic data and abstract were imported from PubMed on 26 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 16
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement