Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Evaluating the acceptability of virtual reality visual field testing in rural Virginia.

Created on 26 Nov 2026

Authors

Kavin Selvan, Brandon Rinkavage, Nancy Beinlich, Sarah Abouassali, Michelle Lam, Victoria Wu, Omar Al-Dulaimi, Amanda Robinson, Du Cheng, Evan Silverstein, Mary K Daly, Roy Sabo, Surbhi Bansal

Published in

PloS one. Volume 21. Issue 11. Pages e0361218. Epub Nov 25, 2026.

Abstract

To evaluate the acceptability of virtual reality (VR)-based visual field (VF) testing using the RetinaLogik Virtual Reality Headset Perimeter (RVF100) device in rural Virginia.
We conducted a cross-sectional study at Remote Area Medical (RAM) vision clinics in medically underserved areas of rural Virginia. Participants were 99 adults (198 eyes) aged 18 years or older with a best-corrected visual acuity of 20/200 or better in both eyes. Participants completed VF testing using the RVF100. Acceptability was assessed using the System Usability Scale (SUS), supplemented by measures of willingness to retest, dizziness or discomfort, and test completion. SUS scores were summarized descriptively and analyzed using a Gaussian generalized linear model with a log-link to examine associations with prespecified covariates.
The median SUS score was 80.00 (A- grade, 85th-89th percentile). Willingness to retest was reported by 90/99 participants (90.9%; Wilson 95% CI, 83.6%-95.1%), 75/99 felt confident using the device (75.8%; Wilson 95% CI, 66.5%-83.1%), and 16/99 reported dizziness or discomfort (16.2%; Wilson 95% CI, 10.2%-24.7%). All 99 participants completed testing (100.0%; Wilson 95% CI, 96.3%-100.0%). Median pattern standard deviation was 1.51 dB in the right eye and 1.47 dB in the left eye; median mean deviation was -0.49 dB in both eyes, and median bilateral assessment duration was 4.78 minutes. No prespecified regression predictor met α = 0.05.
VR-based VF testing was well accepted by participants attending rural outreach clinics and was feasible within the outreach workflow. These findings are limited to patient acceptability in a relatively young cohort in which pre-existing ocular disease and visual field status were not systematically characterized. They do not establish diagnostic accuracy or clinical effectiveness, which require direct comparison with standard automated perimetry in the populations for whom perimetry is indicated.

PMID:
43084466
Bibliographic data and abstract were imported from PubMed on 26 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement