Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Smart Colorimetric Hydrogel Patches with AI-Driven Rational Design for Continuous Temperature Monitoring.

Created on 27 Nov 2026

Authors

Fei Han, Bin Li, Xuebiao Li, Hao Liu, Jiahui Li, Mei Liu, Yanshen Yang, Xuanfan Liu, Yihang Zhao, Chaoyu Cao, Rongyan He, Yunsheng Fang, Qingzhen Yang, Zhao Wei, J Justin Gooding, Feng Xu, Ting Wen

Published in

ACS sensors. Nov 26, 2026. Epub Nov 26, 2026.

Abstract

Continuous temperature monitoring is crucial for advancing personalized healthcare and enhancing biomedical applications. However, existing monitoring devices face significant challenges, including the risk of skin damage from adhesives and reliance on external power sources, leaving a gap in the development of efficient and non-invasive solutions. Here, we present a novel AI-driven inverse-design framework for fabricating colorimetric hydrogel patches (CHPs) with programmable adhesion, offering a more precise and scalable approach than traditional experimental forward design, which relies on labor-intensive and time-consuming experiments to address complex nonlinear design trade-offs. By leveraging multilayer perceptrons (MLPs), data-driven inverse design quickly evaluates thousands of candidate formulations and then works backward to determine the optimal experimental parameters for key performance multi-objectives, such as response time, lower critical solution temperature (LCST), adhesion, stability, and elongation (e.g., material types and dimensions) for rapid customization. We demonstrated that this AI-enabled materials design achieves high accuracy with R2 > 0.95 and much lower root mean square error (RMSE) than traditional interpolation methods, confirming its effectiveness in customizing CHPs for specific biomedical applications. This data-driven methodology enhances the design and functionality of CHPs and uncovers non-intuitive designs validated experimentally in vivo and ex vivo with superior performance across clinical applications such as infant care, wound care, and post-operative care. The integration of AI not only facilitates the adaptability and efficiency of wearable devices but also establishes a pathway toward more sophisticated and personalized healthcare.

PMID:
43097480
Bibliographic data and abstract were imported from PubMed on 27 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement