Reversed airflow during asynchronous volume controlled mechanical ventilation in Out-of-Hospital Cardiac Arrest: a physiological observational study.

Created on 27 Nov 2026

Authors

Christophe Duchatelet, Marie Vergotte, Thomas Tackaert, Maxim Vanwulpen, Said Hachimi-Idrissi

Published in

Resuscitation. Pages 111415. Nov 26, 2026. Epub Nov 26, 2026.

Abstract

Chest compressions during the inspiratory phase of a ventilation can force air out of the lungs, so-called reversed airflow. Human data on this phenomenon during mechanical ventilation are lacking. We aimed to quantify its frequency and magnitude during asynchronous mechanical ventilation in intubated adult out-of-hospital cardiac arrest patients receiving continuous chest compressions.
This single-centre descriptive cross-sectional study used prospectively collected data from patients treated by a physician-staffed prehospital team. After tracheal intubation, patients were ventilated with an Oxylog 3000 transport ventilator in volume-controlled mode without positive end-expiratory pressure, during continuous manual chest compressions. Intratracheal pressures recorded via two catheters allowed calculation of airflow and ventilation parameters during the first minute after intubation. Reversed airflow was defined as expiratory airflow during the inspiratory phase of a mechanical breath. Continuous data are reported as median (first-third quartile).
Twelve patients were included (median age 68 years [62-75]; 7 [58.3%] male), of whom 5 (41.7%) achieved sustained return of spontaneous circulation. Reversed airflow occurred in 10 (83.3%; 95% CI 55.2-95.3) patients and in 141 of 172 (82.0%; 95% CI 75.6-87.0) analysed ventilations. The median reversed-airflow volume was 61 mL [42-80] per episode. Median ventilation rate was 14 breaths/min [13-16], gross inspiratory tidal volume 324 mL [305-345], minute ventilation 4.8 L/min [3.8-5.9], and peak inspiratory pressure 46 cmH2O [40-52].
Reversed airflow occurred frequently during asynchronous volume-controlled mechanical ventilation with the Oxylog 3000 in intubated out-of-hospital cardiac arrest patients receiving continuous manual chest compressions. Its physiological and clinical implications require further investigation.

PMID:
43098503
Bibliographic data and abstract were imported from PubMed on 27 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 82
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement