The vertical velocity step test and vertical sinusoidal harmonic acceleration test.

Created on 27 Nov 2026

Authors

Fumihiro Mochizuki, Erin Williams, Madison Hawthorne, Bernat Miro, Alexander Kiderman, Michael Hoffer

Published in

medRxiv : the preprint server for health sciences. Nov 18, 2026. Epub Nov 18, 2026.

Abstract

Current rotational chair testing assesses only horizontal semicircular canal (SCC) function. This study characterizes vertical SCC responses and provides preliminary descriptive reference ranges using sinusoidal harmonic acceleration (vSHA) and velocity step (vVST) paradigms.
Forty-one healthy adults were tested with an adapted rotational chair to position the left anterior-right posterior (LARP) and right anterior-left posterior (RALP) SCCs in the Earth-horizontal plane. vSHA (at 0.08, 0.16, and 0.64 Hz) and vVST (at 100⁰/s) were performed. Gain, phase, asymmetry, time constants (TC), and maximum slow-phase eye velocity (MSPEV) were compared across planes. Correlations with video head impulse test (vHIT) gain were also examined.
vSHA gain (LARP: 0.37-0.43; RALP: 0.38-0.42) was lower than horizontal gain (0.59-0.63), consistent with previously reported vertical canal measurements. Cross-plane Friedman tests confirmed significantly lower vertical than horizontal gain at all three frequencies (all p < .001). Vertical phase lead exceeded horizontal at 0.08 and 0.16 Hz (all p-adjusted ≤ .021). Vertical TC were significantly shorter than horizontal for both per- and post-rotation (all p-adjusted < .001), and per- and post-rotation TC did not differ significantly in any plane. No significant LARP-RALP differences or vHIT-vVST correlations were found.
vSHA and vVST characterize vertical SCC function non-redundantly with horizontal testing and vHIT. In the vertical planes, gain values and TCs were reduced, which represents a pattern consistent with reduced velocity storage. Validation in larger and clinical samples is required before clinical adoption.

PMID:
43100286
Bibliographic data and abstract were imported from PubMed on 27 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 18
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement